General Description:
When attempting to program multiple devices at the same time, JDRIVE returns
the following error message:
...Error - only 1 action is allowed and 2 are defined.
Aborted.
JDRIVE cannot program multiple devices in the same run. Only one device may
be programmed at a time, with the others in bypass.
To resolve this problem, create a new .cmd file with the correct commands.
Example:
2 Virtex devices in the same chain.
CORRECT command file:
device2 -b"xcv100_pq240_1532.bsd" -a "program" -d"xcv100_pq240.isc";
device1 -i5;
INCORRECT command file:
device2 -b"xcv100_pq240_1532.bsd" -a "program" -d"xcv100_pq240.isc";
device1 -b"xcv100_pq240_1532.bsd" -a "program" -d"xcv100_pq240.isc";
AR# 10778 | |
---|---|
日付 | 05/14/2014 |
ステータス | アーカイブ |
種類 | 一般 |