AR# 1153

6.0 PPR - ERROR 1173: the file \path\dsn.lca associated with the LCA cell \path\dsn could not be found.

説明

Design Manager\Flow Engine stops with a pr 1173 error

*** PPR: ERROR 1173:
The file "\path\my_dsn.lca" associated with the LCA cell
"\path\my_dsn" could not be found.

PPR Terminating due to error status from subtool.

ソリューション

If an LCA file on a drive other than the one the xproject is on is used as a guide file then
PPR will return

*** PPR: ERROR 1173:
The file "\path\my_dsn.lca" associated with the LCA cell
"\path\my_dsn" could not be found.

If a guide .lca file on either a second local drive or on a network drive is selected PPR may fail with the message above.

The problem occurs because the software does not specify a drive before the path

If the LCA file is moved to the same drive as the project then this error goes away.