Proflow : Project Verification Error

説明

Upon entering Proflow you may get the following error message :

Stop : Project Verfication Error:

Proflow will then display the environment data and shut down.

ソリューション

One cause of this problem is when the current project number is too large
in the project.lst file. The number on the first line of this file must be
at least one number less than the total number of directories listed in the
file. Open the <proser>/standard/vf/project.lst and change this number to
0 so that it will now point to the first directory. A sample project.lst
file look like the following :

2 <----- Try changing this number to 0
c:\designs\mydesign
c:\others\urdesign
c:\demos\pci