General Description:
I am having trouble with Schematic Editor in Foundation Classic in error-checking during schematic save and netlist generation -- the following error message is reported:

"Sc :Too many signals: checking for sourceless, loadless nets and multiple drivers aborted.
Sc: Number of detected signals: 1351"

How can I avoid this error?

ソリューション

This error occurs because there is a limit of 1024 signals on a single sheet.

To work around this, split your design up over multiple sheets.