AR# 12177: 4.2i Foundation Schematic Editor - Error: "Sc :Too many signals: checking for sourceless, loadless nets and multiple drivers aborted..."
AR# 12177
|
4.2i Foundation Schematic Editor - Error: "Sc :Too many signals: checking for sourceless, loadless nets and multiple drivers aborted..."
説明
Keywords: Sc, Error, Aldec, Schematic, aborted, Foundation
Urgency: Standard
General Description: I am having trouble with Schematic Editor in Foundation Classic in error-checking during schematic save and netlist generation -- the following error message is reported:
"Sc :Too many signals: checking for sourceless, loadless nets and multiple drivers aborted. Sc: Number of detected signals: 1351"
How can I avoid this error?
ソリューション
This error occurs because there is a limit of 1024 signals on a single sheet.
To work around this, split your design up over multiple sheets.