AR# 17018

|

5.2i iMPACT - Unable to program 9500XL with read protect in concurrent mode

説明

General Description: 

When programming 9500xl and XPLA3 devices in concurrent mode with "read protect" selected, I see the following error in iMPACT 5.2.01i: 

 

"Unsupported command - setPromOptionBits invoked 

, Please make sure that the command is supported on this device. 

PROGRESS_END - End Operation. 

Elapsed time = 1 sec."

ソリューション

Disable concurrent mode and program in sequential mode. 

 

In iMPACT, go to Edit -> Preferences and deselect the Concurrent Mode (CPLD & PROM) box. 

 

This issue is fixed in 6.1i iMPACT.