AR# 19075

6.2 EDK、REVUP - ML300 Design 5 を開くと「No name (IO_IF) specified」というエラー メッセージが表示される

説明

キーワード : ML300, EDK, Design 5, PPC, MPD, デザイン, エラー

重要度 : 標準

概要 :
EDK 6.2 で ML300 Design 5 を開くと、次のようなエラー メッセージが表示されます。
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:24 - No name (IO_IF) specified"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:25 - No name (IO_IF) specified"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:158 - No IO_INTERFACE cpudbg_0 found as specified for PORT C405JTGTDO"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:163 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TCK"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:164 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TDI"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:165 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TMS"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:166 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TRSTNEG"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:172 - No IO_INTERFACE cpudbg_0 found as specified for PORT DBGC405DEBUGHALT"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:175 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCCYCLE"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:176 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCEVENEXECUTIONSTATUS"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:177 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCODDEXECUTIONSTATUS"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:178 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCTRACESTATUS"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:179 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCTRIGGEREVENTOUT"
"ERROR:MDT - H:xroadstesting_examples_62ML300design_5projectsml300_edk2pcoresppc405_v2_00_bdatappc405_v2_1_0.mpd:182 - No IO_INTERFACE trace_0 found as specified for PORT TRCC405TRIGGEREVENTIN"

ソリューション

ML300 Design 5 で、PPC405 コアは pcore です。 この pcore に関連した ppc405_v2_1_0.mpd ファイルに無効な構文が含まれています。 この問題を回避するには、次の手順に従います。
1. ppc405_v2_00_b pcore ディレクトリを削除します。
2. プロジェクトをいったん閉じます。
3. プロジェクトをもう一度開きます。
AR# 19075
日付 04/09/2007
ステータス アーカイブ
種類 一般
このページをブックマークに追加