AR# 29549

Spartan-3E/-3A/-3AN - 「ERROR:PhysDesignRules:792 when using the DCM with Variable Phase Shift in High Frequency Mode」というエラー メッセージが表示される

説明

キーワード : Digital Clock Managers, variable phase shift, High Frequency, MAP error, デジタル クロック マネージャ, 可変位相シフト, 高周波数, マップ, エラー

次のエラーの原因は何ですか。

"ERROR ERROR:PhysDesignRules:792 - Illegal configuration for block XX/YDcm. The
cell < DCM> has the following precondition programming
<DLL_FREQUENCY_MODE>:<HIGH>. The cell < DCM>, has the following
precondition mode <CLKOUT_PHASE_SHIFT> defined as being used. The cell
< DCM>, must have the following programming <CLKOUT_PHASE_SHIFT>:<NONE>.
ERROR:Pack:1642 - Errors in physical DRC."

これは、Spartan-3E/-3A/-3AN をターゲットにした場合の ISE 9.2.03 で、高周波数モードの可変位相シフトが付いた DCM を使用すると発生します。

ソリューション

これは、MAP で発生する無効なエラーです。Spartan-3E/-3A/-3AN の DCM では、高周波数モードで可変位相シフトが使用できます。この問題は、周波数モードを Low に設定すると回避できます。Spartan-3E/-3A/-3AN DCMs には自動周波数センサーが付いているので、DCM はこの設定でもハードウェアで問題なく動作します。

この問題は、今後のソフトウェア リリースで修正される予定です。