UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 30279

10.1 EDK SP2, plbv46_pci_v1_02_a - The latest Tactical Patch "plbv46_pci_v1_03_a" fixes issues related to Linux booting on Ml510 system, Virtex-4 Q, Virtex-4 QR support and various other issues

説明

The following are the latest "plbv46_pci_v1_03_a" fixes: 

 

- Fix for Virtex-5 to correct PCI BARs that were erroneously enabled when the parameter "C_PCIBAR_NUM" was less than 3. 

- Enhancement to increase PCI BAR length upper limit from 29 to 30 (power of 2) bytes. 

- Fix for SERR_N asserted during PCI2PLB read to allow prefetch to complete. 

- Moved to plbv46_slave_v1.01.b, not a functional difference. 

- Fix for Linux booting in ml510 where Linux/compiler optimization breaks up a configuration read 32-bit word operation into 4 separate byte read operations. The byte reads occurred quickly one after another and exposed an issue where the last byte read would be corrupt. 

- Added support for Virtex-4 Q and Virtex-4 QR.

ソリューション

Please use the latest tactical patch (below) in EDK 10.1 sp3. Please see (Xilinx Answer 31638).  

 

http://www.xilinx.com/txpatches/pub/applications/pci/plbv46_pci_v1_03_a_090808.zip
 

Older Patch: 

http://www.xilinx.com/txpatches/pub/applications/misc/patch02122008.zip
 

Unzip and place the "plbv46_pci_v1_03_a" directory in the local "pcore" directory of your current project. 

 

The issue will be fixed in the plbv46_pci_v1_03_a version in EDK 11.1, available at:  

http://www.xilinx.com/xlnx/xil_sw_updates_home.jsp

アンサー レコード リファレンス

関連アンサー レコード

Answer Number アンサータイトル 問題の発生したバージョン 修正バージョン
38095 ML510 - 既知の問題、リリース ノート、マスター アンサー レコード N/A N/A
AR# 30279
日付 05/22/2014
ステータス アーカイブ
種類 一般
このページをブックマークに追加