AR# 3204

M1.4, Map, 5200,-r ,-pr , basut: Error:basut - Switch "-r" is not allowed.

説明

Keywords: M1.4, Map, 5200, basut, switch

Urgency: Standard

General Description:
While targetting a 5200 device, in M1.4, an error is produced by Map:

Error:basut - Switch "-r" is not allowed
or
Error:basut - Switch "-pr" is not allowed

ソリューション

The -pr switch error comes from the use of the option to "Pack I/O Registers/Latches into IOBs for".
(Implement-Options-Edit_Implementation_Template-Map_Options).
By default this option is set to OFF. When set to off, this error will not occur.

The -r switch error comes from the use of the option to "Pack CLB Registers for".
(Implement-Options-Edit_Implementation_Template-Map_Options)
By default this option is set to Structure. When set to Structure, this error
will not occur.