UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 32913

LogiCORE Video Timing Controller v1.0 - Why do some Max Lines Per Frame values cause an "XST failed for v_timebase_v1_0" error during generation?

説明

Why do some Max Lines Per Frame values cause an "XST failed for v_timebase_v1_0" error during generation? 

 

"ERROR:sim - Error: XST failed for v_timebase_v1_0. ERROR:Xst:2587 - Port <det_v0active_start> of instance <U0> has different type in definition <v_timebase_v1_0>."

ソリューション

This is a known issue in the core that is fixed in the Video Timing Controller v2.0. 

 

You can work around this problem by setting the Max Lines Per Frame to a value that is a power of 2. 

 

For example, if you had set the value to 1000 lines and received an error, you can change this to 1024 which is a power of 2. 

 

 

For a detailed list of LogiCORE Video Timing Controller Release Notes and Known Issues, see (Xilinx Answer 32754).

アンサー レコード リファレンス

関連アンサー レコード

Answer Number アンサータイトル 問題の発生したバージョン 修正バージョン
32754 LogiCORE IP Video Timing Controller - リリース ノートおよび既知の問題 N/A N/A
AR# 32913
日付 05/21/2014
ステータス アーカイブ
種類 一般
このページをブックマークに追加