AR# 33520

|

12.4/13.4/14.7 Spartan-6 配置 - 「ERROR:Place:543 for design that should fit」というエラー メッセージが表示される

説明


デザインがフィットしないという次のようなエラー メッセージが表示されます。

デザインにエリア制約は設定されておらず、ターゲット デバイスに問題なく収まるはずです。

何が問題ですか。

ERROR:Place:543 - This design does not fit into the number of slices available
in this device due to the complexity of the design and/or constraints.

Unplaced instances by type:

FF 2 (0.0%)
LUT 2 (0.0%)
LUTL 4 (0.1%)

Please evaluate the following:

- If there are user-defined constraints or area groups:
Please look at the "User-defined constraints" section below to determine
what constraints might be impacting the fitting of this design.
Evaluate if they can be moved, removed or resized to allow for fitting.
Verify that they do not overlap or conflict with clock region restrictions.
See the clock region reports in the MAP log file (*map) for more details
on clock region usage.

- If there is difficulty in placing LUTs:
Try using the MAP LUT Combining Option (map lc area|auto|off).

- If there is difficulty in placing FFs:
Evaluate the number and configuration of the control sets in your design.

The following instances are the last set of instances that failed to place:

0. Placer RPM "BelCluster" (size: 8)
...

ソリューション


デバイスにフィットするはずのデザインでこのエラーが発生する既知の問題があります。

メッセージで「BelCluster」という文字列を検索してください。

この文字列がある場合は、環境変数を設定するとこの問題を回避できます。

注記 : このアンサーは、エラー メッセージに「BelCluster」という文字列がある場合にのみ適用されます。

Place:545 エラーはフィット エラーで、このアンサーとは無関係のさまざま理由でも発生します。

Linux
setenv XIL_PAR_NO_STAGE2_CLS 1

Windows
SET XIL_PAR_NO_STAGE2_CLS=1

ISE 環境変数を設定する一般的な情報については、(Xilinx Answer 11630) を参照してください。