AR# 36252

14.x XPower Analyzer(XPA) - 「WARNING:POWER:1369/1338 - Clock frequency for one or more clocks was not found through timing constraints (PCF file) or simulation data」という警告メッセージが表示される

説明


XPA を実行すると、次のような警告メッセージが表示されます。

WARNING:POWER:1338 - Clock frequency for one or more clocks was not found through timing constraints (PCF file) or simulation data. Without knowing the clock frequency of all clocks, dynamic power information for those clock domains will default to zero which may under-estimate the power for this design.To avoid this warning, provide at least one of the following:

1. The proper timing constraints (PERIOD) for clocks (re-implement design and load the newly generated PCF file into XPower Analyzer)
2. A post PAR simulation-generated VCD or SAIF file indicating clock frequencies
3. The clock frequency for clocks in the "Clocks By Type" view in the XPower Analyzer GUI and then applying "Estimate Activity Rates"

WARNING:POWER:1369 - Clock frequency for one or more clocks was not found through timing constraints (PCF file) or simulation data.Without knowing the clock frequency of all clocks, dynamic power information for those clock domains will default to zero which may under-estimate the power for this design. To avoid this warning, provide at least one of the following:

1. The proper timing constraints (PERIOD) for clocks (re-implement design and load the newly generated PCF file into XPower Analyzer)
2. A post PAR simulation-generated VCD or SAIF file indicating clock frequencies
3. The clock frequency for clocks in the "By Type -> Clocks" view in the XPower Analyzer GUI and then applying "Update Power Analysis"

これらの警告メッセージに対処するにはどうすればよいでしょうか。




ソリューション

警告メッセージにあるように、XPower Analyzer はシミュレーション ファイル (VCD または SAIF) または制約ファイル (PCF) から必要なクロック周波数データを読み出すことができません。この場合、問題の対象となるクロック ドメインのクロック周波数が 0 となり、消費電力が低く見積もられてしまいます。

この問題を回避するには、メッセージにある回避策のいずれかを使用してください。