AR# 38048: 10.1i CPLD Timing Report - Some failed paths are neglected in the HTML report statistic table
AR# 38048
|
10.1i CPLD Timing Report - Some failed paths are neglected in the HTML report statistic table
説明
10.1i Timing Report some failed paths are neglected in the HTML report statistic table
ソリューション
If there are two clocks which are invertions of each and only one Period constraint is applied to the source clock. If there are paths between the two clock domains are not met these paths are listed in the Description section of the Period Constraint in the DETAILED timing report but are neglected in the statistic table.
To workaround the issue the customer should check the Period constraint description section.