AR# 38417

12.2 EDK - "ERROR:EDK:3710 - INSTANCE:RS232_Uart_2 PORT:ctsN - ../system.mhs line 425 - isvalid port in use..."

説明


Base System Builder (BSB) で 2 番目の UART を 16550 デバイスとして選択した割り込みを使用する ML410 デザインを作成すると、次のようなエラー メッセージが表示されます。

"ERROR:EDK:3710 - INSTANCE:RS232_Uart_2 PORT:ctsN -../system.mhs line 425 - isvalid port in use when ISVALID="(C_USE_MODEM_PORTS==1)" evaluates to FALSE.

Please remove the port from your design!

ERROR:EDK:3710 - INSTANCE:RS232_Uart_2 PORT:rtsN - ../system.mhs line 425 - isvalid port in use when ISVALID="(C_USE_MODEM_PORTS==1)" evaluates to FALSE.

Please remove the port from your design!

ERROR:EDK:440 - platgen failed with errors!

make: *** [implementation/system.bmm] Error 2"

この問題の解決方法を教えてください。

ソリューション


この問題は、デザインから ctsN および rtsN ポートを削除するか、C_USE_MODEM_PORTS を 1 に設定すると解決できます。

この問題は、EDK 12.3 で修正される予定です。