UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 38450

12.2 EDK、XPS_MCH_EMC - 「ERROR:EDK:3193 - issued from TCL procedure」というエラー メッセージが表示される

説明

フラッシュ パーツに接続するため XPS MCH EMC コアをコンフィギュレートしています。 


合成中に次のようなエラー メッセージが表示されます。

 

ERROR:EDK:3193 - issued from TCL procedure "hw_emc_common_v4_01_a::check_max_mem_width" line 21 xps_mch_emc_0 (xps_mch_emc) - Invalid xps_mch_emc_0 parameter:
C_MAX_MEM_WIDTH must be the maximum value among width of memory bank data bus
ERROR:EDK:3193 - issued from TCL procedure "check_dwidth_matching_and_num_channels" line 14 xps_mch_emc_0 (xps_mch_emc) - Invalid xps_mch_emc_0 parameter:C_INCLUDE_DATAWIDTH_MATCHING_0,  C_INCLUDE_DATAWIDTH_MATCHING_0 = 0 only if C_MEM0_WIDTH = C_MCH_NATIVE_DWIDTH

ソリューション

C_MAX_MEM_WIDTH がメモリ バンク データ バスの幅の最大値に等しい値ではないため、これはエラーです。

 

フラッシュ パーツが 1 つある場合は、C_MAX_MEM_WIDTH および C_MEM0_WIDTH は等しくなるはずです。

AR# 38450
作成日 10/05/2010
最終更新日 01/19/2015
ステータス アクティブ
タイプ エラー メッセージ
ツール
  • EDK - 12.1
  • EDK - 12.2
  • EDK - 12.3
IP
  • XPS Multi-CHannel External Memory Controller