UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

このページをブックマークに追加

AR# 4156

M1.5 Timing analysis doesn't use TPTHRU as more specific than FROM:TO

説明

FROM:THRU:TO, Constraints.

General Description: Timing analysis doesn't prioritize a FROM:THRU:TO

as more specific than FROM:TO.

ソリューション

The resolution is to place a PRIORITY on the FROM:THRU:TO

Example:

TIMESPEC TS01=FROM:FFS:THRU:ABC:TO:FFS:20:PRIORITY:1;

This will cause TRCE to analyze this above all other FROM:TO

timespecs in the design.

AR# 4156
日付 01/18/2010
ステータス アーカイブ
タイプ 一般