When running the Foundation F1.5 Project Manager, you may see the following error:
Automation Caused an Exception: Exit Code 80010104, 800706ba
ソリューション
1
One solution has been to reinstall the software, making sure to install the default set of libraries along with any other device families you wish to use. With Foundation F1.5, certain dependancy issues between device data files existed, and this issue is resolved by installing all of the default devices. We also advise users to first uninstall the software before reinstalling it.
2
This error has been seen to occur after installing the Xilinx 1.5 Service Pack #1. The Foundation 1.5i software may have been working properly before installing the Service Pack, then this automation error occurs after the Service Pack is installed.
If you have installed the Foundation Express update, be sure to run the batch file called "license_upd.bat". This batch file will update required DLLs and will re-initialize the automation.
Reboot the system after installing the Service Pack and the error should go away.
3
If running under Windows NT, be sure that you have administrative priviledges when you install. If you do not, the registry will not be updated, and these errors will occur. The automation of the Foundation tools relies on the registry being properly updated by the installer.
4
This can happen with a Base or Base Express if the XC3100L family is installed WITHOUT the XC3000L. It does not matter if you are targetting this family or not, you will still get the errors if 3100L is even installed and 3000L is not.
To resolve it, you have 2 choices:
If you wish to use the XC3100L family, then you must also install the XC3000L. Refer to (Xilinx Solution 4583) for information on adding additional devices to the install.
If you do not wish to use the XC3100L family, then do not install it at all.
This particular cause of the problem is fixed in the F1.5i release.
5
In both 1.5 and 1.5i, this problem can occur when opening a project or trying to implement a project. The project will open with errors or a project will not implement at all.
The reason for this error is because the PATH variable in the environment settings is not pointing to the correct path. Be sure that the PATH variable is pointing to $XILINX\bin\nt.
This can be checked: in NT-- right click on MY COMPUTER => Properties => Environment Tab.