AR# 4898

F1.5, Schematic Editor: Issues involving complex buses; removal of Bus Pin Connection function

説明

Keywords: complex, bus, bus pin connection, migrate, migration

Urgency: Hot

General Description:

In F1.5, changes have been made to the way in which complex buses are implemented in the Schematic Editor. The change involved the removal of the Bus Pin Connection function which was available in F1.4 and was used to define the signal order
for complex buses going into bus pins. This function was removed because it is no longer necessary with the new implementation of the complex bus structures. Instead of placing the definition of the bus pin order in the Bus Pin Connection dialog, you now simply place this same definition, or bus label, on the actual bus segment which is going into the bus pin. The Online Help topic "Using Buses" discusses this feature in more detail.

When a design which used the Bus Pin Connection function in F1.4 is
migrated to F1.5, the Bus Pin Connection label is moved down onto the
bus which is connected to the respective bus pin. The connectivity of the
bus to the bus pin is defined by this label.

A problem exists, however, for some designs which were using the Bus
Pin Connections in F1.4 and are migrated to F1.5. When the Bus Pin
Connection label is moved down to the respective bus, it may rename
the bus with this Bus Pin Connection label, even if the bus had been
labeled differently in F1.4. This causes segments of the bus to have
incorrect labels, and thus the logic in the design to be connected
incorrectly.

ソリューション

Unfortunately, the only workaround in F1.5 for this problem of bus names
being changed incorrectly during a design migration, is to manually
re-label the buses properly.

This problem is being addressed in F1.5i, and the conversion will be done
properly in this next release.