UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 5285

1.5i 4KXL Map: FATAL_ERROR:baste:bastegrp.c:477:1.21 - No output pin for group

説明

Keywords: map, fatal, error, baste, bastegrp, output, pin, group

Urgency: Standard

General Description: When executing the following command line:

map -u -p XC4044XL-BG352-3 fx4

the following error occurs

FATAL_ERROR:baste:bastegrp.c:477:1.21 - No output pin for group

ソリューション

1

The work around that the customer found out is to put -p option after -o
option and it takes care of the problem. Project Manager GUI however, puts -p first by default which consistently leads to error.

2

This problem only ocurrs for this case when the trimming of unused logic
is disabled (-u). The work around is to not disable trimming.

A fix for this problem will be included in version 2.1 due to be released in June 1999.
AR# 5285
作成日 12/22/1998
最終更新日 04/25/2000
ステータス アーカイブ