UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 55726

2013.1 Vivado IP フロー - Vivado IP コアをアップグレードしようとるすると「ERROR: [IP_Flow 19-503] Validation failed for parameter...」というエラー メッセージが表示される

説明

Vivado 2013.1 ツールで、ある IP コアをアップグレードしようとすると、次のような警告およびエラー メッセージが表示されます。

7 Series GT Wizard v2.4

upgrade_ip -vlnv xilinx.com:ip:gtwizard:2.5 [get_ips  my_gtwizard]

Removed parameter gtz0_val_reference_clock
Removed parameter gtz1_val_reference_clockRemoved parameter gtz2_val_reference_clock
Removed parameter gtz3_val_reference_clockWARNING: [IP_Flow 19-2191] Attempt to set value '00000000' on disabled parameter 'gt0_val_clk_cor_seq_2_3' is ignored
WARNING: [IP_Flow 19-2191] Attempt to set value '00000000' on disabled parameter 'gt0_val_clk_cor_seq_2_4' is ignoredERROR: [IP_Flow 19-503] Validation failed for parameter 'gt_type'.



For this device GTX is disabled. So please select other options
ERROR: [IP_Flow 19-3196] Value 'DFE-Auto_(no_sliding_TAP)' is out of the range for parameter 'gt0_val_dfe_mode'.
Valid values are - DFE-Auto, DFE-Manual, LPM-Auto.
ERROR: [IP_Flow 19-3235] Customization errors found. Encountered problem restoring previous valid configuration, see errors below.
ERROR: [IP_Flow 19-503] Validation failed for parameter 'gt_type'. For this device GTX is disabled. So please select other options
ERROR: [IP_Flow 19-3196] Value 'left_column' is out of the range for parameter 'gt_column'.
Valid values are - right_column.
ERROR: [IP_Flow 19-503] Validation failed for parameter 'gt0_val'. No Active Transceivers!

ERROR: [IP_Flow 19-503] Validation failed for parameter 'gt1_val'. No Active Transceivers!

ERROR: [IP_Flow 19-503] Validation failed for parameter 'gt2_val'. No Active Transceivers!

FIFO Generator v10.0

upgrade_ip -vlnv xilinx.com:ip:fifo_generator:10.0 [get_ips afifo]

WARNING: [IP_Flow 19-2191] Attempt to set value '1023' on disabled parameter 'Full_Threshold_Assert_Value_wach' is ignored
...
ERROR: [IP_Flow 19-508] Validation failed for parameter 'Full_Threshold_Assert_Value_wach'. Value '1' is out of the range (6,1023)

エラーは表示されますが、IP は問題なくアップグレードされたようです。 

ソリューション

このコアのアップグレードが正しく処理されていません。

Vivado 2013.1 ツールでこの問題を解決するには、このアンサーの最後にあるOS 別のパッチと、アップグレードしようとしている IP のパッチを共にインストールします。

インストール方法については readme ファイルを参照してください。

この問題は Vivado 2013.2 ツールで修正される予定で、その時点でこのパッチは不要になります。

添付ファイル

関連添付ファイル

AR# 55726
日付 05/06/2013
ステータス アーカイブ
種類 既知の問題
ツール