デザインのフロアプラン後、次のエラー メッセージが表示されます。

"ERROR:Pack:679 - Unable to obey design constraints (LOC = B14) which require the combination of the following symbols into a single I/O component:
PAD symbol "RdEnFifo2_N.PAD" (Pad Signal = RdEnFifo2_N)
BUF symbol "RdEnFifo2_N_obuf" (Output Signal = RdEnFifo2_N)
The symbol RdEnFifo2_N.PAD has a constraint (LOC=B14) that specifies an illegal physical site for the component. Please correct the constraint value. Please correct the design constraints accordingly."

"ERROR:Pack:276 - Unable to follow packing constraints specified by the floorplanner. Refer to the error messages above to determine why the floorplan constraints are not followed. The floorplan may need to be modified."

ソリューション

このエラーは、Floorplanner がデザインのグローバル サイトに不正な I/O 制約を指定するために発生します。 これは制約の指定がない I/O で発生します。(制約の指定がない I/O はグローバル サイトに配置すべきではありません。) Floorplanner を開いて、これらの不正な I/O 制約がデザインで見つかった場合、新しい MFP ファイルを保存したときに MAP エラーが発生します。

この問題を解決するには、手動で不正な制約を Floorplanner ないで変更し、もう一度保存してください。 新しい FNF および MFP ファイルが保存された後、配置が正しく行われます。